Compatibility

GatePilot does not replace your existing installation, it is added to it: it works with an ONVIF/RTSP compatible IP camera, a relay contact input on the barrier controller and a Windows computer. Fixed-code 433 MHz remotes can be taught to the system, and the existing barrier and automation are not removed. Before installation the existing camera's stream and resolution and the controller's inputs are checked, and compatibility is confirmed by that review.

Camera: an ONVIF/RTSP compatible IP camera

The system is designed to work with ONVIF/RTSP compatible IP cameras. If your existing camera meets that condition it can be used; if there is no camera, or it is not sufficient for plate reading, the camera configuration is determined together with the number of gates and cameras.

The condition is not a particular brand or model: the camera must be ONVIF/RTSP compatible and its stream must be good enough for plate reading. This is confirmed in the check made before installation.

Connection: a relay contact output

GatePilot delivers the gate command to the barrier controller through a relay contact output. The controller therefore needs a suitable relay/contact input reserved for the open command.

The logic of the existing automation does not change; the system connects to the controller's existing open input. If the controller has no suitable input, that comes out in the review made before the quote and installation.

Remotes: fixed-code 433 MHz

Fixed-code 433 MHz remotes can be taught to the system. Where a remote-controlled routine is wanted, it continues to be used alongside the system.

The same gate can therefore serve both plate recognition and the existing remotes; the familiar routine does not have to change all at once.

Computer: Windows and NVIDIA/CUDA

The system runs on a Windows computer and is designed and sized for NVIDIA/CUDA. No separate recording device is needed.

The computer configuration is determined by the number of gates and cameras; the suitability of your existing computer is assessed at the quote stage.

Checking the existing system before installation

Compatibility is confirmed by a review carried out before installation. The review covers:

  • The camera's stream, resolution and ONVIF/RTSP compatibility
  • The open input and relay connection on the barrier controller
  • The way the gate and automation operate
  • The computer configuration for the number of gates and cameras

Frequently asked questions

Can my existing camera be used?
If the camera is ONVIF/RTSP compatible it can be used. Before installation its stream and resolution are checked.
What does my barrier controller need to have?
It needs a suitable relay/contact input for the open command. This is looked at during the check made before installation.
Will my existing remotes keep working?
Fixed-code 433 MHz remotes can be taught to the system. If you want it, the remote-controlled routine continues alongside the system.
Will my existing barrier be replaced?
No. GatePilot is added to the existing automation; the barrier and the automation are not removed and stay in place.
What kind of computer is required?
The system is designed for a Windows computer and sized for NVIDIA/CUDA. The configuration is determined at the quote stage according to the number of gates and cameras.
Which barrier and camera brands does it work with?
On the camera side the condition is ONVIF/RTSP compatibility; on the barrier side it is a suitable relay/contact input on the controller. Regardless of brand or model, the existing system is checked before installation.

Related pages

Tell us about your gate and we will size the configuration together.

Get a quote

Last updated: 2026-10-05